Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.advisor | ||
dc.contributor.author | Jansová, Magdalena | |
dc.contributor.author | Hynčík, Luděk | |
dc.contributor.author | Čechová, Hana | |
dc.contributor.author | Toczyski, J. | |
dc.contributor.author | Gierczycka-Zbrozek, D. | |
dc.contributor.author | Baudrit, P. | |
dc.date.accessioned | 2015-09-02T06:36:19Z | |
dc.date.available | 2015-09-02T06:36:19Z | |
dc.date.issued | 2015 | |
dc.identifier.citation | Applied and Computational Mechanics. 2015, vol. 9, no. 1, p. 5-20 | en |
dc.identifier.issn | 1802-680X (Print) | |
dc.identifier.issn | 2336-1182 (Online) | |
dc.identifier.uri | http://www.kme.zcu.cz/acm/acm/article/view/285/326 | |
dc.identifier.uri | http://hdl.handle.net/11025/15513 | |
dc.description.abstract | The study focused on the validation of the 50 th percentile male model — a detailed FE model of the thoracic segment of the human body developed within project Development of a Finite Element Model of the Human Thorax and Upper Extremities (THOMO) co-funded by the European Commission (7 th Framework Programme). The model response was tested in three impact scenarios: frontal, lateral and oblique. The resulting impactor contact force vs. time and chest deflection vs. time responses were compared with experimental results. The strain profile of the 5th rib was checked with lateral and oblique strain profiles from post-mortem human subject (PMHS) experiments. The influence of heart and lungs on the mechanical response of the model was assessed and the material data configuration, giving the most biofidelic thorax behaviour, was identified. | en |
dc.format | 16 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | University of West Bohemia | en |
dc.relation.ispartofseries | Applied and Computational Mechanics | en |
dc.rights | © 2015 University of West Bohemia. All rights reserved. | en |
dc.subject | výpočtová mechanika | cs |
dc.subject | model lidského těla | cs |
dc.subject | thorax | cs |
dc.title | Evaluation of human thorax FE model in various impact scenarios | en |
dc.type | článek | cs |
dc.type | article | en |
dc.rights.access | openAccess | en |
dc.type.version | publishedVersion | en |
dc.subject.translated | model of human body | en |
dc.subject.translated | thorax | en |
dc.subject.translated | computational mechanics | en |
dc.type.status | Peer-reviewed | en |
Vyskytuje se v kolekcích: | Volume 9, number 1 (2015) Články / Articles (NTIS) Články / Articles (MMI) Články / Articles (CTM) Volume 9, number 1 (2015) |
Soubory připojené k záznamu:
Soubor | Popis | Velikost | Formát | |
---|---|---|---|---|
Jansova.pdf | 4,35 MB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/15513
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.