Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorKadlečíková, Magdaléna
dc.contributor.authorBreza, Juraj
dc.contributor.authorKlotton, G.
dc.contributor.authorKolmačka, Michal
dc.contributor.authorVančo, Ľubomír
dc.contributor.editorPihera, Josef
dc.contributor.editorSteiner, František
dc.date.accessioned2016-02-04T07:46:42Z
dc.date.available2016-02-04T07:46:42Z
dc.date.issued2016
dc.identifier.citationElectroscope. 2016, č. 1.cs
dc.identifier.issn1802-4564
dc.identifier.urihttp://147.228.94.30/images/PDF/Rocnik2016/Cislo1_2016/r10c1c6.pdf
dc.identifier.urihttp://hdl.handle.net/11025/17670
dc.description.abstractHF CVD (hot filament chemical vapour deposition) reaktor je technologické zariadenie, v ktorom sa na rôznych substrátoch syntetizujú uhlíkové nanorúr ky. Reaktor pracuje na princípe pyrolýzy metánu a vodíka. Substrát je umiestnený na molybdénovom držiaku niekoľko milimetrov pod žeravenými (2200 °C) volfrámovými vláknami a jeho teplota počas syntézy je optimalizovaná cca na 600 °C. Merania a regulácie teploty rotačného držiaku v priebehu syntézy sa vykonáva teplomerom s bezdrôtovým optickým prenosom dát. Počas prevádzky zariadenia sa v yskytol závažný probl é m, a to nestabilné napájanie, čo viedlo ku kolísaniu teploty v reaktore. To je dôvod, prečo bolo navrhnuté iné riešenie za použitia impulzného napájacieho zdroja. Merací reťazec bol zjednodušený od stránením mobilných kontaktov a izolačných zosilňovačov, ktoré po prehriatí pracovali ne s p r ávne a skresľovali údaje o teplote. Výsledkom tejto práce je návrh a rekonštrukcia obvodov napájajúcich merač teploty v HF CVD reaktore.sk
dc.format4 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherZápadočeská univerzita v Plzni, Fakulta elektrotechnickács
dc.relation.ispartofseriesElectroscopecs
dc.rightsCopyright © 2015 Electroscope. All Rights Reserved.en
dc.subjectuhlíkové nanotrubičkycs
dc.subjectHF CVD reaktorcs
dc.subjectpulzní napájecí zdrojcs
dc.titleRedesign of the supply electronics of the temperature gauge in a HF CVD reactoren
dc.title.alternativeRekonštrukcia napájacích obvodov merača teploty v HF CVD reaktoresk
dc.typečlánekcs
dc.typearticleen
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedHF CVD (hot filament chemical vapour deposition) reactor is a technological apparatus in which carbon nanotubes are synthesized on various substrates. The reactor operates on the principle of pyrolysis of methane and hydrogen. The substrate is placed on a molybdenum holder, several millimetres below hot (2200 °C) tungsten filaments and its temperature during synthesis is optimized to approximately 600 °C. Measurement and control of the temperature of the rotating holder during synthesis are carried out by a temperatur e gauge with wireless optical data transfer. During operation of the facility a severe drawback was encountered, namely instable supplying resulting in temperature fluctuations in the reactor. This is why another solution has been designed utilizing a swit ched mode power supply. The measurement string has been simplified by removing mobile contacts and isolation amplifiers that behaved incorrectly – when they became overheated – and distorted the data on temperature. The result of the present work is the de sign and reconstruction of the circuitry supplying the temperature meter in the HF CVD reactor.en
dc.subject.translatedcarbon nanotubesen
dc.subject.translatedHF CVD reactoren
dc.subject.translatedpulse mode power supplyen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:Číslo 1 (2016)
Číslo 1 (2016)

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
r10c1c6.pdfPlný text453,89 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/17670