Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.author | Hurda, Lukáš | |
dc.contributor.author | Matas, Richard | |
dc.date.accessioned | 2018-04-04T09:03:52Z | - |
dc.date.available | 2018-04-04T09:03:52Z | - |
dc.date.issued | 2017 | |
dc.identifier.citation | HURDA, L., MATAS, R. Uncertainty analysis of thermal quantities measurement in a centrifugal compressor. In 36th Meeting of Departments of Fluid Mechanics and Thermodynamics. Melville, NY: Amer Inst Physics, USA, 2017. s.1-8. ISBN 978-0-7354-1572-0 , ISSN 0094-243X. | en |
dc.identifier.isbn | 978-0-7354-1572-0 | |
dc.identifier.issn | 0094-243X | |
dc.identifier.uri | 2-s2.0-85030749701 | |
dc.identifier.uri | http://hdl.handle.net/11025/29496 | |
dc.identifier.uri | https://aip.scitation.org/journal/apc | |
dc.description.abstract | Proces vyhodnocení charakteristik kompresoru založený na měření tlaku, teploty a dalších veličin byl podroben analýze s cílem zjistit nejistoty pro přímo měřené a odvozené veličiny. Jako nástroj pro kvantifikaci vlivů různých zdrojů nejistoty měření pro sondy s termočlánky byla použit CFD simulace. Vedení tepla tělesem termočlánkové sondy a ohřev vzduchu v sacím potrubí a jejich vliv na měřené teploty jsou hlavním objektem zájmu. | cs |
dc.format | 8 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | Amer Inst Physics | en |
dc.relation.ispartofseries | 36th Meeting of Departments of Fluid Mechanics and Thermodynamics | en |
dc.rights | Plný text není přístupný. | cs |
dc.rights | © Amer. Inst. Physics | en |
dc.subject | Odstředivý kompresor, termočlánky, termodynamický proces | cs |
dc.title | Analýza nejistot měření tepelných veličin v odstředivém kompresoru | cs |
dc.title | Uncertainty analysis of thermal quantities measurement in a centrifugal compressor | en |
dc.type | konferenční příspěvek | cs |
dc.type | conferenceObject | en |
dc.rights.access | closedAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | Compressor performance characteristics evaluation process based on the measurement of pressure, temperature and other quantities is examined to find uncertainties for directly measured and derived quantities. CFD is used as a tool to quantify the influences of different sources of uncertainty of measurements for single- and multi-thermocouple total temperature probes. The heat conduction through the body of the thermocouple probe and the heat-up of the air in the intake piping are the main phenomena of interest. | en |
dc.subject.translated | Centrifugal compressor | en |
dc.subject.translated | thermocouples | en |
dc.subject.translated | thermodynamic process | en |
dc.identifier.doi | 10.1063/1.5004346 | |
dc.type.status | Peer-reviewed | en |
dc.identifier.document-number | 417391000012 | |
dc.identifier.obd | 43921603 | |
dc.project.ID | SGS-2016-045/Zvyšování účinnosti, spolehlivosti a životnosti energetických strojů a zařízení 4 | cs |
Vyskytuje se v kolekcích: | Konferenční příspěvky / Conference papers (MIS) OBD |
Soubory připojené k záznamu:
Soubor | Velikost | Formát | |
---|---|---|---|
1.5004346_Matas.pdf | 1,2 MB | Adobe PDF | Zobrazit/otevřít Vyžádat kopii |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/29496