Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.author | Akbarov, R.A. | |
dc.contributor.author | Nuruyev, S.M. | |
dc.contributor.author | Ahmadov, G.S. | |
dc.contributor.author | Ahmadov, F.I. | |
dc.contributor.author | Tyutyunnikov, S.I. | |
dc.contributor.author | Sadigov, A.Z. | |
dc.contributor.author | Mammadov, R. | |
dc.contributor.author | Holík, Michael | |
dc.contributor.author | Berikov, D. | |
dc.contributor.author | Kopatch, Yu. | |
dc.date.accessioned | 2020-08-31T10:00:25Z | - |
dc.date.available | 2020-08-31T10:00:25Z | - |
dc.date.issued | 2020 | |
dc.identifier.citation | AKBAROV, R., NURUYEV, S., AHMADOV, G., AHMADOV, F., TYUTYUNNIKOV, S., SADIGOV, A., MAMMADOV, R., HOLÍK, M., BERIKOV, D., KOPATCH, Y. Scintillation readout with MAPD array for gamma spectrometer. Journal of Instrumentation, 2020, roč. 15, č. 1, s. 0-7. ISSN 1748-0221. | en |
dc.identifier.issn | 1748-0221 | |
dc.identifier.uri | 2-s2.0-85081206474 | |
dc.identifier.uri | http://hdl.handle.net/11025/39570 | |
dc.format | 8 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | IOP Publishing | en |
dc.relation.ispartofseries | Journal of Instrumentation | en |
dc.rights | Plný text je přístupný v rámci univerzity přihlášeným uživatelům. | cs |
dc.rights | © IOP Publishing | en |
dc.title | Scintillation readout with MAPD array for gamma spectrometer | en |
dc.type | článek | cs |
dc.type | article | en |
dc.rights.access | restrictedAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | In this study, we present the gamma-ray detection performance of LYSO, YSO(Ce) and BGO scintillators read out by a 9 ch. micropixel avalanche photodiode (MAPD) array with a high pixel density (PD) and photon detection efficiency (PDE). The array with an active area of 11,5x11,5mm2 was assembled using single MAPDs with an active area of 3,7x3,7mm2. It had a single output signal and was developed for gamma spectroscopy. Breakdown voltage measurements were carried out for each channel, as a result of which the optimal operating voltage for the array was found. The linearity range and energy resolution for each crystal were determined in the energy range from 30 to 1770 keV. The high pixel density of the array allowed to achieve good linearity in the studied energy range. | en |
dc.subject.translated | photon detectors for UV | en |
dc.subject.translated | visible and IR photons | en |
dc.subject.translated | solid-state | en |
dc.subject.translated | PIN diodes | en |
dc.subject.translated | APDs | en |
dc.subject.translated | Si-PMTs | en |
dc.subject.translated | G-APDs | en |
dc.subject.translated | CCDs | en |
dc.subject.translated | EBCCDs | en |
dc.subject.translated | EMCCDs | en |
dc.subject.translated | CMOS imagers | en |
dc.subject.translated | scintillators | en |
dc.subject.translated | scintillation and light emission processes | en |
dc.identifier.doi | 10.1088/1748-0221/15/01/C01001 | |
dc.type.status | Peer-reviewed | en |
dc.identifier.document-number | 525449100001 | |
dc.identifier.obd | 43929944 | |
dc.project.ID | EF16_019/0000766/Inženýrské aplikace fyziky mikrosvěta | cs |
Vyskytuje se v kolekcích: | Články / Articles (KAE) OBD |
Soubory připojené k záznamu:
Soubor | Velikost | Formát | |
---|---|---|---|
2020 JINST 15 C01001 - Scintillation readout with MAPD array for gammaspectrometer.pdf | 819,87 kB | Adobe PDF | Zobrazit/otevřít Vyžádat kopii |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/39570
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.