Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorKubíková, Tereza
dc.date.accessioned2021-11-01T11:00:32Z-
dc.date.available2021-11-01T11:00:32Z-
dc.date.issued2021
dc.identifier.citationKUBÍKOVÁ, T. The air flow around a milling cutter investigated experimentally by particle image velocimetry. In AIP Conference Proceedings. Pilsen: American Institute of Physics, 2021. s. 030006-1-030006-8. ISBN: 978-0-7354-4067-8 , ISSN: 0094-243Xcs
dc.identifier.isbn978-0-7354-4067-8
dc.identifier.issn0094-243X
dc.identifier.uri2-s2.0-85102737408
dc.identifier.urihttp://hdl.handle.net/11025/45602
dc.format8 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherAmerican Institute of Physicsen
dc.relation.ispartofseriesAIP Conference Proceedingsen
dc.rights© authorsen
dc.titleThe air flow around a milling cutter investigated experimentally by particle image velocimetryen
dc.typekonferenční příspěvekcs
dc.typeConferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThe movement of air around a rotating milling cutter is investigated experimentally by using the optical non-intrusive method PIV (Particle Image Velocimetry). The milling cutter is located next to a flat surface simulating the processed material. The Flow is studied in three planes in axial × radial direction with phases 90°, 180° and 270° from the point closest to the flat desk. The PIV timing has been synchronized with the cutter rotation. We observed plumes governed by centrifugal force (as in Taylor-Couette flow) acting on the air teared with the rotating milling cutter. In average, the air flows along the milling cutter from its front end forming a large-scale vortex mostly apparent at higher velocity and at the plane opposite to the processed surface. At the 90°plane, the air is sucked towards the milling cutter, while at the 270°plane, the air is pushed away from it. Spatial correlation function shows a weak periodicity close to the cutter and widening of its shape with increasing distance from the milling cutter.en
dc.subject.translatedMilling cutteren
dc.subject.translatedParticle Image Velocimetryen
dc.subject.translatedCorrelation functionen
dc.identifier.doi10.1063/5.0041860
dc.type.statusPeer-revieweden
dc.identifier.document-number668075000020
dc.identifier.obd43932921
Vyskytuje se v kolekcích:OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
5.0041860.pdf3,41 MBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/45602

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD