Název: | Solvent Evaporation Rate as a Tool for Tuning the Performance of a Solid Polymer Electrolyte Gas Sensor |
Autoři: | Sedlák, Petr Kašpar, Pavel Sobola, Dinara Gajdoš, Adam Majzner, Jiří Sedláková, Vlasta Kuberský, Petr |
Citace zdrojového dokumentu: | SEDLÁK, P. KAŠPAR, P. SOBOLA, D. GAJDOŠ, A. MAJZNER, J. SEDLÁKOVÁ, V. KUBERSKÝ, P. Solvent Evaporation Rate as a Tool for Tuning the Performance of a Solid Polymer Electrolyte Gas Sensor . Polymers, 2022, roč. 14, č. 21, s. 1-17. ISSN: 2073-4360 |
Datum vydání: | 2022 |
Nakladatel: | MDPI |
Typ dokumentu: | článek article |
URI: | 2-s2.0-85141840449 http://hdl.handle.net/11025/50953 |
ISSN: | 2073-4360 |
Klíčová slova v dalším jazyce: | solid polymer electrolyte;gas sensor;noise spectroscopy;ionic liquid |
Abstrakt v dalším jazyce: | Solid polymer electrolytes show their potential to partially replace conventional electrolytes in electrochemical devices. The solvent evaporation rate represents one of many options for modifying the electrode-electrolyte interface by affecting the structural and electrical properties of polymer electrolytes used in batteries. This paper evaluates the effect of solvent evaporation during the preparation of solid polymer electrolytes on the overall performance of an amperometric gas sensor. A mixture of the polymer host, solvent and an ionic liquid was thermally treated under different evaporation rates to prepare four polymer electrolytes. A carbon nanotube-based working electrode deposited by spray-coating the polymer electrolyte layer allowed the preparation of the electrode-electrolyte interface with different morphologies, which were then investigated using scanning electron microscopy and Raman spectroscopy. All prepared sensors were exposed to nitrogen dioxide concentration of 0-10 ppm, and the current responses and their fluctuations were analyzed. Electrochemical impedance spectroscopy was used to describe the sensor with an equivalent electric circuit. Experimental results showed that a higher solvent evaporation rate leads to lower sensor sensitivity, affects associated parameters (such as the detection/quantification limit) and increases the limit of the maximum current flowing through the sensor, while the other properties (hysteresis, repeatability, response time, recovery time) change insignificantly. |
Práva: | © authors |
Vyskytuje se v kolekcích: | Články / Articles (KET) OBD |
Soubory připojené k záznamu:
Soubor | Velikost | Formát | |
---|---|---|---|
Kubersky_polymers-14-04758.pdf | 5,49 MB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/50953