Title: Model-based bias controller for a Mach-Zehnder intensity modulator
Authors: Švarný, Jiří
Chládek, Svatoslav
Citation: ŠVARNÝ, J. CHLÁDEK, S. Model-based bias controller for a Mach-Zehnder intensity modulator. JOURNAL OF LIGHTWAVE TECHNOLOGY, 2022, roč. 40, č. 3, s. 720-727. ISSN: 0733-8724
Issue Date: 2022
Publisher: IEEE
Document type: článek
article
URI: 2-s2.0-85118535402
http://hdl.handle.net/11025/47494
ISSN: 0733-8724
Keywords in different language: bias control;electro-optic modulator;harmonic analysis;mach-zehnder modulator drift;model-based controller
Abstract: A new dither technique is presented to control the bias voltage of an intensity modulator of the Mach-Zehnder type to maintain the quadrature operating point. This method is based on the direct calculation of the operating point deviation. The calculation uses an exactmathematicalmodel of themodulator.The data used for calculating the deviation value are obtained from an analysis based on a fast Fourier transform with a properly set level of vector averaging. Unlike other solutions, the proposed feedback system does not use an approach with a proportional-integral or proportional-integral-derivative controller. Moreover, the presented stabilization method is robust and invariant regarding changes in the input optical power of themodulator and immune to prospective fluctuations of most of the feedback loop parameters. With the proposed approach in its present form, a 3-hour stability of ±0.08° is achieved. This value reflects the limitations of the equipment used. Even better results can be expected using more powerful hardware.
Abstract in different language: A new dither technique is presented to control the bias voltage of an intensity modulator of the Mach-Zehnder type to maintain the quadrature operating point. This method is based on the direct calculation of the operating point deviation. The calculation uses an exactmathematicalmodel of themodulator.The data used for calculating the deviation value are obtained from an analysis based on a fast Fourier transform with a properly set level of vector averaging. Unlike other solutions, the proposed feedback system does not use an approach with a proportional-integral or proportional-integral-derivative controller. Moreover, the presented stabilization method is robust and invariant regarding changes in the input optical power of themodulator and immune to prospective fluctuations of most of the feedback loop parameters. With the proposed approach in its present form, a 3-hour stability of ±0.08° is achieved. This value reflects the limitations of the equipment used. Even better results can be expected using more powerful hardware.
Rights: Plný text je přístupný v rámci univerzity přihlášeným uživatelům.
© IEEE
Appears in Collections:Články / Articles (RICE)
Články / Articles (KET)
OBD

Files in This Item:
File SizeFormat 
Svarny_Model-Based.pdf2,94 MBAdobe PDFView/Open    Request a copy


Please use this identifier to cite or link to this item: http://hdl.handle.net/11025/47494

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.