Title: | Minimally Invasive Fixation Techniques of Sacral Bone Fractures |
Authors: | Marešová, Michaela Lobovský, Libor Mandys, Tomáš Salášek, Martin Hartlová, Jana Pavelka, Tomáš Křen, Jiří |
Citation: | MAREŠOVÁ, M. LOBOVSKÝ, L. MANDYS, T. SALÁŠEK, M. HARTLOVÁ, J. PAVELKA, T. KŘEN, J. Minimally Invasive Fixation Techniques of Sacral Bone Fractures. In EAN 2021 - 59th International Scientific Conference on Experimental Stress Analysis. Praha: Czech Technical University – CTU in Prague, Faculty of Civil Engineering, Department of Mechanics, 2022. s. 120-124. ISBN: 978-80-01-06885-4 |
Issue Date: | 2022 |
Publisher: | Czech Technical University – CTU in Prague, Faculty of Civil Engineering, Department of Mechanics |
Document type: | konferenční příspěvek ConferenceObject |
URI: | 2-s2.0-85129785841 http://hdl.handle.net/11025/49808 |
ISBN: | 978-80-01-06885-4 |
Keywords in different language: | biomechanics;pelvis;injury;osteosynthesis;transiliac internal fixator;iliosacral screw |
Abstract: | The study focuses on minimally invasive fixation techniques of sacral bone fractures by means of the transiliac internal fixator (TIFI). Several implementations of TIFI for unilateral transforaminal fracture treatment are studied both experimentally and computationally. The comparison of fixation techniques is performed on the basis of the calculated stiffness ratio, which is determined from the displacement of the sacrum and the applied external load. The results of the experimental measurements are compared with numerical simulations while a very good agreement is achieved. |
Abstract in different language: | The study focuses on minimally invasive fixation techniques of sacral bone fractures by means of the transiliac internal fixator (TIFI). Several implementations of TIFI for unilateral transforaminal fracture treatment are studied both experimentally and computationally. The comparison of fixation techniques is performed on the basis of the calculated stiffness ratio, which is determined from the displacement of the sacrum and the applied external load. The results of the experimental measurements are compared with numerical simulations while a very good agreement is achieved. |
Rights: | Plný text není přístupný. © Department of Mechanics K132 FSv CVUT |
Appears in Collections: | Konferenční příspěvky / Conference papers (NTIS) OBD |
Files in This Item:
File | Size | Format | |
---|---|---|---|
MaresovaLobovsky_2021.pdf | 18,35 MB | Adobe PDF | View/Open Request a copy |
Please use this identifier to cite or link to this item:
http://hdl.handle.net/11025/49808
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.