Název: Timepix3 detector network for nuclear waste monitoring
Autoři: Biskup, Bartoloměj
Bergmann, Benedikt
Broulím, Pavel
Burian, Petr
Malich, Milan
Mánek, Petr
Meduna, Lukáš
Mora Sierra, Yesid
Pichotka, Martin Peter
Pušman, Lukáš
Rubovič, Peter
Slavíček, Tomáš
Smolyanskiy, Petr
Citace zdrojového dokumentu: BISKUP, B. BERGMANN, B. BROULÍM, P. BURIAN, P. MALICH, M. MÁNEK, P. MEDUNA, L. MORA SIERRA, Y. PICHOTKA, MP. PUŠMAN, L. RUBOVIČ, P. SLAVÍČEK, T. SMOLYANSKIY, P. Timepix3 detector network for nuclear waste monitoring. In EPJ Web of Conferences. Praha: EDP Sciences, 2021. s. 1-4. ISBN: neuvedeno , ISSN: 2100-014X
Datum vydání: 2021
Nakladatel: EDP Sciences
Typ dokumentu: konferenční příspěvek
ConferenceObject
URI: http://hdl.handle.net/11025/47099
ISSN: 2100-014X
Klíčová slova v dalším jazyce: imepix3 detector;nuclear waste monitoring;neutron detection
Abstrakt v dalším jazyce: In the framework of the MICADO project we proposed an active long-term nuclear waste monitoring system based on Timepix3 technology. Particle detectors based on Timepix3 are capable of particle type discrimination and provide spectrometric information in combination with precise timing information. To maximize the versatility of the setup, the Timepix3 detectors employed are equipped with a range of different sensors. To enable measurement of neutrons, two quadrants of the detectors are covered by neutron converters, allowing detection of thermal neutron by capture in 6Li, as well as detection of fast neutrons through recoil protons generated in a polyethylene converter. Within this project a new housing for the detector unit and the readout was developed, with the network currently comprising of 9 such detectors. A specifically developed in-house software handles simultaneous operation of all devices, cluster analysis and data visualization. Energy calibration was performed using an X-ray tube with several fluorescence foils as well as photons from an 241Am source. The neutron and gamma/X-ray detection efficiency calibration was carried out at the Czech Metrology Institute and the results are presented here. Tests on simultaneous operation of all 9 devices were performed using uraninite and 241Am sources.
Práva: © authors
Vyskytuje se v kolekcích:Konferenční příspěvky / Conference papers (RICE)
Konferenční příspěvky / Conference Papers (KEI)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Burian_epjconf_animma2021_07010.pdf575,74 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/47099

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD