Title: | Timepix3 detector network for nuclear waste monitoring |
Authors: | Biskup, Bartoloměj Bergmann, Benedikt Broulím, Pavel Burian, Petr Malich, Milan Mánek, Petr Meduna, Lukáš Mora Sierra, Yesid Pichotka, Martin Peter Pušman, Lukáš Rubovič, Peter Slavíček, Tomáš Smolyanskiy, Petr |
Citation: | BISKUP, B. BERGMANN, B. BROULÍM, P. BURIAN, P. MALICH, M. MÁNEK, P. MEDUNA, L. MORA SIERRA, Y. PICHOTKA, MP. PUŠMAN, L. RUBOVIČ, P. SLAVÍČEK, T. SMOLYANSKIY, P. Timepix3 detector network for nuclear waste monitoring. In EPJ Web of Conferences. Praha: EDP Sciences, 2021. s. 1-4. ISBN: neuvedeno , ISSN: 2100-014X |
Issue Date: | 2021 |
Publisher: | EDP Sciences |
Document type: | konferenční příspěvek ConferenceObject |
URI: | http://hdl.handle.net/11025/47099 |
ISSN: | 2100-014X |
Keywords in different language: | imepix3 detector;nuclear waste monitoring;neutron detection |
Abstract in different language: | In the framework of the MICADO project we proposed an active long-term nuclear waste monitoring system based on Timepix3 technology. Particle detectors based on Timepix3 are capable of particle type discrimination and provide spectrometric information in combination with precise timing information. To maximize the versatility of the setup, the Timepix3 detectors employed are equipped with a range of different sensors. To enable measurement of neutrons, two quadrants of the detectors are covered by neutron converters, allowing detection of thermal neutron by capture in 6Li, as well as detection of fast neutrons through recoil protons generated in a polyethylene converter. Within this project a new housing for the detector unit and the readout was developed, with the network currently comprising of 9 such detectors. A specifically developed in-house software handles simultaneous operation of all devices, cluster analysis and data visualization. Energy calibration was performed using an X-ray tube with several fluorescence foils as well as photons from an 241Am source. The neutron and gamma/X-ray detection efficiency calibration was carried out at the Czech Metrology Institute and the results are presented here. Tests on simultaneous operation of all 9 devices were performed using uraninite and 241Am sources. |
Rights: | © authors |
Appears in Collections: | Konferenční příspěvky / Conference papers (RICE) Konferenční příspěvky / Conference Papers (KEI) OBD |
Files in This Item:
File | Size | Format | |
---|---|---|---|
Burian_epjconf_animma2021_07010.pdf | 575,74 kB | Adobe PDF | View/Open |
Please use this identifier to cite or link to this item:
http://hdl.handle.net/11025/47099
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.